TECHNICAL NOTE (92001)

Summary: Logitec Mouseware hangs after resume in Windows
Date: September 29, 1995
Product: As Listed
Solution: See Below
Additional Information: None

The T3400CT, T3600CT, T2400CT & CS all use the Logitec Mouseware driver. If your mouse pointer hangs after resuming from Windows, follow the following procedure:

1). Type SETUP in your Windows directory.

2). Move highlight bar to "MSDOS SYSTEM" and hit enter

3). Select MS-DOS SYSTEM with APM

4). Put in the appropiate W4W diskette according to displayed message

_______________________________________________________________

Toshiba America Information Systems Inc. (" TAIS ") shall not be liable for damages of any kind for use of this information, Which is subject to change without notice. Copyright 1994, 1995 TAIS.