_______________________________________________________________
Summary: | D-Link 651 PCMCIA ethernet adapter |
Date: | September 29, 1995 |
Product: | As specified |
Problem / Issue: | Compatibility & Configuration |
The D-Link 651 PCMCIA ethernet adapter was successfully tested in the T3400CT and the T3300SL.
Testing on the T3400CT was done using Toshiba Card Manager v1.0. The following configuration should work fine with any systems which support PCMCIA.
Testing on the T3300SL was done using a driver provided by D-Link designed specifically for the T3300SL.
CONFIGURATION FOR THE T3400CT
CONFIG.SYS
DEVICE=C:\DOS\HIMEM.SYS
DEVICE=C:\DOS\EMM386.EXE noems x=c800-CBFF X=D600-DBFF
FILES=30
DOS=UMB
LASTDRIVE=E
FCBS=4,0
DOS=HIGH
STACKS=9,256
[COMMON]
DEVICE=C:\PCMPLUS\PCMSS.EXE
DEVICE=C:\PCMPLUS\PCMCS.EXE /WAIT=20 /ADDR=C8 /IRQ=10 DEVICE=C:\PCMPLUS\PCMSCD.EXE /LANIRQ=5
NET.CFG
LINK DRIVER DE650ODI
INT 5 (Set interrupt to 5) PORT 320 (Set I/O port to 320)
MEM D6000 (Set memory address to D6000) FRAME ETHERNET_802.3
**** IMPORTANT *****
The 'PORT' parameter must be set to 320 and the 'MEM' parameter must be at D6000 for the adapter to initialize. This is required only when using the Phoenix drivers (Toshiba Card Manager).
AUTOEXEC.BAT or NET.BAT
LSL
DE650ODI
IPXODI
NETX
CONFIGURATION for T3300SL
CONFIG.SYS
DEVICE=C:\dos\HIMEM.SYS
DEVICE=C:\DOS\EMM386.EXE NOEMS X=D000-D7FF DEVICE=C:\DOS\SETVER.EXE
DOS=HIGH,umb
FILES=60
BUFFERS=25
DEVICEHIGH=C:\DOS\ANSI.SYS
STACKS=0,0
AUTOEXEC.BAT or NET.BAT
DCD (D-Link driver - or use ICCNT.EXE) LSL
DE650ODI
IPXODI
NETX
_______________________________________________________________
Toshiba America Information Systems Inc. (" TAIS ") shall not be liable for damages of any kind for use of this information, Which is subject to change without notice. Copyright 1994, 1995 TAIS.